Study on Ventilation Volume of EV in the Case of Transport for COVID-19 Patient (Part5)
コロナ患者の移送をEV車で実施する際の換気量の研究(その5)
- Delivery
- Available on this site
- Format
- Price
- Non-members (tax incl.):¥1,100 Members (tax incl.):¥880
- Publication code
- 20265199
- Paper/Info type
- Proceedings (Spring)
No.48-26
- Pages
- 1-4(Total 4 p)
- Date of publication
- May 2026
- Publisher
- JSAE
- Language
- Japanese
- Event
- 2026 JSAE Annual Congress (Spring)
Detailed Information
| Author(J) | 1) 押野 幸一 |
|---|---|
| Author(E) | 1) Koichi Oshino |
| Affiliation(J) | 1) - |
| Affiliation(E) | 1) - |
| Abstract(J) | コロナ患者の移送時には,車室内の換気が重要となる.前報では,車窓の開口高さが小さい場合,外気導入時の換気量に注目し,窓開口高さと換気量の関係を得た.車両が外気導入時に十分な換気量を有していると既報から推定される.本報では,(1案)外気導入のみよる換気,(2案)窓開口高さが小さい場合の換気を提案したい. Translation |
| Abstract(E) | Cabin ventilation is important in the case of transport for COVD-19 patients. At the previous report, it was obtained the relation between small opening window height and the ventilation volume. It is predicted that the vehicles have the satisfied ventilation volume on the outside air inducing method at the previous report. Here, I would like to submit following two methods. First one is the ventilation of the outside air inducing method, second one is that of the small opening window height method. |