ログインしてください

文献・情報検索システム

日本語

ENGLISH

ヘルプ

ログインしてください

  • 詳細情報

A PN-Measurement System for Small Engine Applications

書誌事項

著者(英)1) Sebastian Schurl, 2) Martin Kupper, 3) Helmut Krasa, 4) Stephan Schmidt, 5) Stefan Sturm, 6) Andreas Heidinger
勤務先(英)1) Graz University of Technology, 2) Graz University of Technology, 3) Graz University of Technology, 4) Graz University of Technology, 5) Graz University of Technology, 6) Graz University of Technology
抄録(英)Particulates are among the most harmful emission components of internal combustion engines (ICE)). Thus, emission limits have been widely introduced, e.g., for light- and heavy-duty vehicles. Although there are still engine applications without particulate limitations, the measurement of particulate mass (PM) and particulate number (PN) emissions is therefore of special interest for the development and operation of ICE. For this purpose, a measurement system for PN consisting of a custom-built sample conditioning and dilution system, and a TSI 3790-A10 condensation particle counter (CPC) as particle number counter (PNC) was designed and built. In this work, we present the conditioning and dilution system, the operational parameters, and results from the particle concentration reduction factor (PCRF) calibration. The sampling system was developed in accordance with the current global technical regulations (GTR15) and consists of a heated sampling probe, up to three dilution stages and a catalytic stripper for volatile particle removal (VPR). In order to be able to cover a variety of engines and provide the wide measurement range of eleven orders of magnitude, further dilution stages were implemented in the system. With the help of a variable mixing chamber dilution and an additional ejector diluter, PCRFs between 1:200 and 1:5000 can be used. The primary dilution stage consists of an ejector-diluter calibrated to a dilution ratio of 1:23,4 at 20 °C. The catalytic stripper arranged in the system consists of an oxidation catalyst and a sulphate trap. A PCRF calibration was done using a Jing miniCAST as a particle source, producing a polydisperse combustion aerosol which is passed through a dilution bridge, a VPR and a differential mobility analyzer (DMA). The DMA allows to select monodisperse modes according to mobility diameters of the particles. The PCRF was measured by a reference CPC (TSI 3775). Calibrations were done at 15, 23, 41, 60 and 100 nm for the eight different dilutions, resulting in 40 measurements.

翻訳

検索について

閉じる

検索ボックスの使い方

検索条件は最大5件まで入力可能です。検索ボックスの数は右側の「+」「−」ボタンで増減させることができます。
一つの検索ボックス内に、複数の語句をスペース(全角/半角)区切りで入力した場合、入力した語句の“すべてを含む”データが検索されます(AND検索)。
例)X(スペース)Y →「XかつY(を含む)」

「AND」「OR」プルダウンの使い方

「AND」を指定すると、前後の検索ボックスに入力された語句の“双方を含む”データが検索されます。また、「OR」を指定すると、前後の検索ボックスに入力された語句の“いずれかを含む”データが検索されます。
例)X AND Y →「XかつY(を含む)」  X OR Z →「XまたはZ(を含む)」
AND検索とOR検索が混在する場合は、OR検索が優先されます。
例)X AND Y OR Z → X AND (Y OR Z)
AND検索と複数のOR検索が混在する場合も、OR検索が優先されます。
例)W AND X OR Y OR Z → W AND (X OR Y OR Z)

検索フィルタの使い方

検索結果の件数が多すぎる場合など、さらに絞り込みしたいときに「検索フィルタ」を使います。各項目にチェックを入れると、その項目が含まれるデータのみに検索結果が絞り込まれます。
各項目後ろの「()」内の数字は、その項目が含まれるデータの件数です。

検索のコツ

著者名で検索するときは、「自動車 太郎」のように、姓名をスペースで区切って入力してください。