FPGA Implementation of In-Cycle Closed-Loop Combustion Control Methods

書誌事項

著者(英)1) Carlos Jorques Moreno, 2) Ola Stenlaas, 3) Per Tunestal
勤務先(英)1) Scania CV AB, 2) Scania CV AB, 3) Lund University
抄録(英)This paper investigates the FPGA resources for the implementation of in-cycle closed-loop combustion control algorithms. Closed-loop combustion control obtains feedback from fast in-cylinder pressure measurements for accurate and reliable information about the combustion progress, synchronized with the flywheel encoder. In-cycle combustion control requires accurate and fast computations for their real-time execution. A compromise between accuracy and computation complexity must be selected for an effective combustion control. The requirements on the signal processing (evaluation rate and digital resolution) are investigated. A common practice for the combustion supervision is to monitor the heat release rate. For its calculation, different methods for the computation of the cylinder volume and heat capacity ratio are compared. Combustion feedback requires of virtual sensors for the misfire detection, burnt fuel mass and pressure prediction. Different alternatives proposed in the literature are compared based on their accuracy and implementation requirements. In-cycle closed-loop combustion controllers were previously investigated by the authors. A National Instruments Xilinx Virtex-5 platform was used as a case study for the quantification of the total necessary resources. The resources for the implementation of the different modules and control strategies are studied to determine the hardware requirements. The results show that the total number of slices is the main limiting factor on the consumed FPGA resources. The quantification of the required hardware provides guidance on how to select an FPGA to implement the different in-cycle combustion control alternatives. This permits to evaluate the total cost of the system as a trade-off between the increased efficiency by the closed-loop combustion control and the cost for its implementation.

翻訳

検索について

閉じる

検索ボックスの使い方

検索条件は最大5件まで入力可能です。検索ボックスの数は右側の「+」「−」ボタンで増減させることができます。
一つの検索ボックス内に、複数の語句をスペース(全角/半角)区切りで入力した場合、入力した語句の“すべてを含む”データが検索されます(AND検索)。
例)X(スペース)Y →「XかつY(を含む)」

「AND」「OR」プルダウンの使い方

「AND」を指定すると、前後の検索ボックスに入力された語句の“双方を含む”データが検索されます。また、「OR」を指定すると、前後の検索ボックスに入力された語句の“いずれかを含む”データが検索されます。
例)X AND Y →「XかつY(を含む)」  X OR Z →「XまたはZ(を含む)」
AND検索とOR検索が混在する場合は、OR検索が優先されます。
例)X AND Y OR Z → X AND (Y OR Z)
AND検索と複数のOR検索が混在する場合も、OR検索が優先されます。
例)W AND X OR Y OR Z → W AND (X OR Y OR Z)

検索フィルタの使い方

検索結果の件数が多すぎる場合など、さらに絞り込みしたいときに「検索フィルタ」を使います。各項目にチェックを入れると、その項目が含まれるデータのみに検索結果が絞り込まれます。
各項目後ろの「()」内の数字は、その項目が含まれるデータの件数です。

検索のコツ

著者名で検索するときは、「自動車 太郎」のように、姓名をスペースで区切って入力してください。