Sizing and Optimization of a Vortex Tube for Electric Vehicle HVAC Purposes

書誌事項

著者(英)1) Daniele Chiappini, 2) Barbara Mendecka, 3) Gino Bella
勤務先(英)1) UNIVERSITA' DEGLI STUDI NICCOLO' CUSANO, 2) University of Tuscia, 3) University Of Rome
抄録(英)In the recent past, an always increasing attention have been addressed to the definition and optimization of the HVAC system for fully electric vehicles. The new vehicle layouts and the different operating temperatures of the whole powertrain ask for a re-thinking of the HVAC concept for the modern architectures. In this ballpark, the possibility to deal with a compact and efficient apparatus without moving parts and capable to provide both cold and hot fluxes is really attractive. This is the reason why this work deals with the design and optimization of a vortex tube for automotive applications. Such a component, in fact, is capable to separate a highly swirled flow in two different branches, a cold one and a hot one (one inlet - two outlets). The balance in between the two obtained mass flows can be simply realized via ruling the backpressure at the hot side, with keeping constant the cold one. After a preliminary sizing activity, where the best compromise in between vortex tube dimensions and achievable mass flow rate has been evaluated, a detailed optimization procedure has been carried out in order to find the optimal operating points so to answer to cooling demand. More specifically, starting from the mass flow and temperature requirements for a critical steady state point referred to a commercial M-class vehicle, the whole sizing/optimization procedure has been developed. Obtained results are pretty encouraging, with appreciable results in terms of cold mass flow rate and realizable cold temperatures. Nevertheless, some additional reasoning should be addressed to the integration of such a component in a working layout, especially in terms of integration with compressors and diffusers to be placed at vortex tube inlet and cold outlet respectively.

翻訳

検索について

閉じる

検索ボックスの使い方

検索条件は最大5件まで入力可能です。検索ボックスの数は右側の「+」「−」ボタンで増減させることができます。
一つの検索ボックス内に、複数の語句をスペース(全角/半角)区切りで入力した場合、入力した語句の“すべてを含む”データが検索されます(AND検索)。
例)X(スペース)Y →「XかつY(を含む)」

「AND」「OR」プルダウンの使い方

「AND」を指定すると、前後の検索ボックスに入力された語句の“双方を含む”データが検索されます。また、「OR」を指定すると、前後の検索ボックスに入力された語句の“いずれかを含む”データが検索されます。
例)X AND Y →「XかつY(を含む)」  X OR Z →「XまたはZ(を含む)」
AND検索とOR検索が混在する場合は、OR検索が優先されます。
例)X AND Y OR Z → X AND (Y OR Z)
AND検索と複数のOR検索が混在する場合も、OR検索が優先されます。
例)W AND X OR Y OR Z → W AND (X OR Y OR Z)

検索フィルタの使い方

検索結果の件数が多すぎる場合など、さらに絞り込みしたいときに「検索フィルタ」を使います。各項目にチェックを入れると、その項目が含まれるデータのみに検索結果が絞り込まれます。
各項目後ろの「()」内の数字は、その項目が含まれるデータの件数です。

検索のコツ

著者名で検索するときは、「自動車 太郎」のように、姓名をスペースで区切って入力してください。